10/2 UF-B Copper Underground Feeder Cable With Ground 1000'

10/2 UF-B Copper Underground Feeder Cable With Ground 1000'

Last price we saw

$1,698.00at Walmart, last seen Nov 3

Prices change often: ask the agent below to check today's price at every store.

Prices are checked against each store and labelled with when.

Ask our shopping agent

Enter to send, Shift+Enter for a new line

Our take on the 10/2 UF-B Copper Underground Feeder Cable With Ground 1000'

This is 1,000 feet of 10-gauge, 2-conductor UF-B cable with a bare ground, rated for 30 amps and built for direct burial. The PVC jacket is sunlight- and moisture-resistant, so it runs underground to outbuildings, pumps and posts without conduit. It is stiff and heavy, so plan the pull and the trench before you buy. No current price was provided for this listing, so compare per-foot pricing across stores before ordering a full 1,000-foot spool.

Best forRunning 30-amp power to a detached garage, shed or well pumpDirect-burial runs that skip conduitOutdoor feeders exposed to sun and wet soilBuyers who need a full 1,000-foot spool for a long run
Pros
  • Rated for direct burial without conduit
  • Sunlight- and moisture-resistant PVC jacket
  • 10-gauge copper carries 30 amps
  • Includes a bare ground conductor
  • 1,000-foot length covers long runs with little waste
Cons
  • Stiff jacket is hard to bend in tight trenches
  • Heavy spool that needs two people to move
  • Copper price makes long runs costly
  • Not for indoor branch wiring where NM-B is allowed

10/2 UF-B Copper Underground Feeder Cable With Ground 1000' prices at every store

  • WalmartCheck price at Walmart

10/2 UF-B Copper Underground Feeder Cable With Ground 1000' price history

Lowest price we've seen: $1,698.00 on Nov 3 at Walmart. Tracked across 1 store since Nov 3.

Specifications

Conductor Material
Copper
Cable Length
1000.0'
Cable Jacket Material
PVC
Amps
30 Amps

Questions and answers

Is 10/2 UF-B safe to bury directly in the ground?
Yes. UF-B is listed for direct burial, so it can go in the soil without conduit. Bury it below the frost line and deep enough to meet local code, and use conduit where it rises out of the ground.
What size breaker does 10/2 UF-B need?
It is rated for 30 amps, so pair it with a 30-amp breaker. Long runs can drop voltage, so check the run length against your load before committing.
Can I use UF-B inside a house?
It is allowed in some indoor locations, but it is stiff and hard to fish through walls. NM-B is easier for indoor branch circuits.
How deep should the trench be?
Local code sets the depth, commonly 24 inches for direct-buried feeder cable. Call 811 before digging and keep the run clear of roots and rocks.
Does it include a ground wire?
Yes. This is 10/2 with ground: two insulated conductors plus a bare ground wire. That ground is required for most 30-amp outdoor circuits.
When is the best time to buy a 1,000-foot spool?
Copper cable prices track metal markets, so spools are cheapest when copper prices dip. Compare per-foot prices across stores before a big order.