10/2 UF-B Copper Underground Feeder Cable With Ground 175'

10/2 UF-B Copper Underground Feeder Cable With Ground 175'

Last price we saw

$293.95at Walmart, last seen Nov 3

Prices change often: ask the agent below to check today's price at every store.

Prices are checked against each store and labelled with when.

Ask our shopping agent

Enter to send, Shift+Enter for a new line

Our take on the 10/2 UF-B Copper Underground Feeder Cable With Ground 175'

This is 175 feet of 10-gauge, two-conductor copper UF-B cable with a ground wire, jacketed in PVC for direct burial. It is the standard cable for running 30-amp circuits underground to a shed, well pump, post light or subpanel. The 175-foot length suits runs that a 125-foot or 250-foot spool would cut too close or waste. Prices for 10/2 UF-B move with copper, so compare the per-foot cost against other lengths before buying.

Best forBuried 30-amp circuits to outbuildingsWell pump and post-light feedsDIYers wiring a detached shed or garageRuns of roughly 150 to 175 feet
Pros
  • Rated for direct burial, no conduit needed in most soil
  • Copper conductors carry 30 amps at 120/240 volts
  • Includes a ground wire for modern code-compliant circuits
  • Sunlight- and moisture-resistant PVC jacket
  • 175-foot length fits mid-length runs without splicing
Cons
  • Copper price makes long runs expensive
  • Heavy and stiff, hard to pull through tight bends
  • Not rated for wet locations inside conduit underground in all jurisdictions
  • Cutting and terminating 10-gauge wire needs proper tools
  • No connectors or fittings included

10/2 UF-B Copper Underground Feeder Cable With Ground 175' prices at every store

  • WalmartCheck price at Walmart

10/2 UF-B Copper Underground Feeder Cable With Ground 175' price history

Lowest price we've seen: $293.95 on Nov 3 at Walmart. Tracked across 1 store since Nov 3.

Specifications

Conductor Material
Copper
Cable Length
175 ft
Cable Jacket Material
PVC

Questions and answers

Is 10/2 UF-B safe to bury directly in the ground?
Yes. UF-B is listed for direct burial, so it can go in soil without conduit in most installations. Check local code for depth requirements, typically 24 inches, and for any conduit needed where it rises out of the ground.
What can I run on 10/2 UF-B?
It supports a 30-amp, 120/240-volt circuit. Common uses are a subpanel in a shed, a well pump, outdoor receptacles or post lights. It is not enough for a large shop with heavy equipment.
How deep does it need to be buried?
The National Electrical Code calls for 24 inches of cover for direct-buried UF cable in most cases. Local rules can be stricter, and you may need conduit or a sleeve where the cable emerges.
Is 10/2 UF-B the same as 10/3?
No. 10/2 has two insulated conductors plus a bare ground. 10/3 adds a second hot wire for circuits that need two switched hots or a 240-volt feed with neutral, such as some dryer and subpanel setups.
Can I use it indoors?
UF-B can be used indoors where code allows, but it is stiff and hard to fish through walls. Most indoor 30-amp runs use 10/2 NM-B instead.
When is the price lowest?
Copper cable prices track metal markets, so they fluctuate week to week. Compare the per-foot price across lengths and stores, and buy when a listing drops below its recent range.