The BC600RNC is a standby UPS rated 600 VA / 300 W. It takes 120 V AC single-phase input and delivers 120 V AC output with a pulse-width modulated sine wave. It backs up home and office computers, networking equipment and point-of-sale gear in retail, kiosks, food service and light industrial settings. A QR code on the unit leads to a cloud monitoring app and web browser for setup, alerts, outlet-bank control and configuration, and an NFC area configures network settings from a mobile device.
The unit has four NEMA 5-15R outlets and is rated for 190 joules of surge suppression, and it filters electromagnetic interference (EMI) and radio frequency interference (RFI). During short blackouts and brownouts it switches to battery power. After a longer outage it restarts automatically once power returns, regardless of battery charge level. The internal battery is user-replaceable, the unit runs self-tests, and a resettable circuit breaker guards against overloads.
An audible alarm and a red LED signal a low battery or fault, and a green LED shows power and line/battery mode; the alarm can be turned off through the monitoring app, which still responds to silenced alarms. The flatpack housing is rated for an operating temperature of 32° to 122°F (0° to 50°C) and can sit on a desktop or the floor. Mounting points on the bottom allow horizontal or vertical mounting in a 100 x 100 mm VESA pattern with the included hardware, and attachment points take user-supplied cable ties for a shelf or beam. The input cable, Ethernet port, outlets, power button and status LEDs are all on the same side, and the five-foot cord ends in a NEMA 5-15P plug.
- Power
- 600 VA / 300 W
- Input
- 120 V AC, single phase
- Output
- 120 V AC, pulse-width modulated sine wave
- Outlets
- 4 x NEMA 5-15R
- Surge suppression
- 190 joules
- Filtering
- EMI and RFI
- Battery
- Internal, user-replaceable
- Recharge time
- 8 hours
- Standby time
- 1.20 minutes
- Self-test
- Yes
- Circuit breaker
- Resettable
- Alarm
- Audible; can be disabled in the app
- Indicators
- Red LED for low battery or fault, green LED for power and line/battery mode
- Monitoring
- Cloud app and web browser; NFC network setup
- Operating temperature
- 32° to 122°F (0° to 50°C)
- Mounting
- Desktop, floor, horizontal or vertical, 100 x 100 mm VESA pattern
- Power cord
- 5 ft with NEMA 5-15P plug
- Housing
- Flatpack