This digital programmable frequency meter has an LCD display. With a prescaler, the range extends to over 1 GHz.
It is built around a PIC microcontroller and follows the Microchip AN592 application note. The input stage uses a common-emitter amplifier with a BFR91 or another fast NPN transistor to raise a 200–300 mV peak-to-peak signal to about 3 V. The PIC runs a 32-bit counter with a 0.4-second counting window.
A menu sets the frequency-averaging mode and value, which can be added to or subtracted from the reading. This makes the meter useful as a frequency reader on receivers and transceivers. Before use, calibrate it with a known frequency and the 33 pF trimmer; a coarse CAL mode is available through pins 10, 12, and 13, and the calibration is saved to non-volatile memory when pin 10 is released.
- Range with prescaler
- Over 1 GHz
- Resolution
- 10 Hz
- Display
- LCD
- Controller
- PIC microcontroller
- Design basis
- Microchip AN592 application note
- Counter
- 32-bit
- Counting window
- 0.4 seconds
- Input level
- 200–300 mV peak-to-peak
- Input amplifier
- Common-emitter with BFR91 or another fast NPN; output about 3 V
- Sensitivity
- High-sensitivity input; measures weak quartz-oscillator signals
- Frequency averaging
- Menu-adjustable mode and value
- IF offset
- Adds or subtracts the intermediate frequency
- Calibration
- 33 pF trimmer; coarse CAL mode via pins 10, 12, and 13; saved to non-volatile memory
- Use
- Frequency reader for receivers and transceivers