In stockReturn policy
| Model | Max PV input | Charge current | Max PV power 12 / 24 / 3 | Max PV short-circuit | Weight |
|---|---|---|---|---|---|
| 150/70 | 150 V | 70 A | 1,000 / 2,000 / 3,000 / | 50 A | 3 kg |
| 150/85 | 150 V | 85 A | 1,200 / 2,400 / 3,600 / | 4.5 kg | |
| 150/100 | 150 V | 100 A | 1,450 / 2,900 / 4,350 / | 4.5 kg | |
| 250/70 | 250 V | 70 A | 1,000 / 2,000 / 3,000 / | 35 A | 3 kg |
| 250/85 | 250 V | 85 A | 1,200 / 2,400 / 3,600 / | 4.5 kg | |
| 250/100 | 250 V | 100 A | 1,450 / 2,900 / 4,350 / | 4.5 kg |
The VE.Can flagship MPPTs — for the largest arrays and multi-controller systems
This is the top of the SmartSolar line: 70, 85, or 100 A of charge current, 150 V or 250 V of PV input, full 12 / 24 / 36 / 48 V support, and — the defining feature — a VE.Can communication port that lets you daisy-chain up to 25 controllers into one synchronised system. If you're building a large off-grid home, a bluewater yacht with a big array, or any system that needs more than one or two MPPTs working as one, this is the range. Bluetooth is built in, and the ultrafast MPPT algorithm runs at up to 98% efficiency on the 150-series, up to 99% on the 250-series.
Who the SmartSolar MPPT VE.Can range is built for
Large off-grid homes — multi-kW arrays on a 48 V bank, often with two or more controllers synchronised over VE.Can.
Bluewater and liveaboard yachts — big arch and bimini arrays needing 70–100 A of charge.
Commercial and professional installs — where VE.Can daisy-chaining and a GX device tie everything into one monitored system.
Installers and system integrators — remote on/off, a programmable relay, and up to 25 units on one VE.Can bus.
How to read the model number
First number = max PV input voltage. 150 V or 250 V — the higher ceiling lets you run more panels in series.
Second number = max charge current. 70, 85, or 100 A into the battery.
Combine those with the maximum PV wattage your system voltage supports to size the controller. Wesley walks through the full math in our MPPT sizing guide .
Why VE.Can?
Every SmartSolar MPPT has VE.Direct and Bluetooth; these models add a VE.Can port. VE.Can lets you daisy-chain up to 25 charge controllers with a single RJ45 cable between each unit and on to a GX device — they synchronise their charge stages and each still reports individually to the GX and the VRM portal. (Over Bluetooth alone, up to 10 units synchronise.) For a single-controller system the non-VE.Can models are fine; choose VE.Can when you're running several MPPTs or want them on the VE.Can backbone alongside the rest of your Victron system. A VE.Can bus needs a 120 Ω terminator at each end — see the accessories below.
Tr or MC4 — which PV connection?
The two versions are electrically identical; they differ only in how the solar wires land:
Tr (screw terminals). One positive and one negative 35 mm² / AWG 2 screw terminal — you bring your own PV wiring. Best for a combined home-run from a combiner box.
MC4. Built-in MC4 connectors (two pairs on the 70 A models, three pairs on the 85 and 100 A models; max 30 A per connector). Best for panel strings wired straight to the controller.
Choose your controller
It checks today's price at every store, compares the alternatives and answers in about a minute.







Model
Max PV input
Charge current
Max PV power 12 / 24 / 36 / 48 V
Max PV short-circuit
Weight